Intelligent-motion-systems MDrive34AC User Manual

Browse online or download User Manual for Safety Intelligent-motion-systems MDrive34AC. Intelligent Motion Systems MDrive34AC User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Mechanical Specifications
MDrive34AC Plus Microstepping Quick Reference R070208
Quick Reference
MDrive34AC Plus
Microstepping
Notes and Warnings
Installation, configuration and maintenance must be carried out by qualified
technicians only. You must have detailed information to be able to carry out this
work. This information can be found in the user manuals.
• Unexpected dangers may be encountered when working with this product!
• Incorrect use may destroy this product and connected components!
The user manuals are not included. You can obtain them from the Internet at:
http://www.imshome.com/mdrive34acplus_mdm.html.
Required for Setup*
PC running Microsoft(r) Windows XP Service Pack 2 or greater.
IMS SPI Motor Interface (available online)
MD-CS200/201-000 or equivalent Lumberg mating connector/cordset for
AC power.
0 to 5 MHz Clock signal for step clock, may be a controller high speed
output or signal generator.
SPST switch or controller I/O point to control axis direction.
I/O and SPI communications interface (Recommended: IMS MD-
CC301-001)
* If you purchased your MDrivePlus with a QuickStart Kit, you have received all
of the connecting cables needed for initial functional setup and system testing.
Getting Started
All documentation, software and resources are available online at:
http://www.imshome.com/mdrive34acplus_mdm.html
Connecting Power and I/O
Your MDrivePlus may be configured with power and I/O combined on a single
connector, or with separate connectors. Please refer to the opposite side of this
document for connecting details and available IMS connectivity options includ-
ing Prototype Development Cables and Mating Connector Kits.
Connecting Communications
Connect IMS USB to SPI communications converter to MDrivePlus and
1.
PC.
Install the communication converter drivers onto PC (available online).2.
Install and open SPI Motor lnterface.3.
Apply power to MDrivePlus.4.
Parameters may be adjusted via two screens, the Motor Settings screen 5.
or the I/O settings screen (shown below), accessible via the View menu.
Motor Settings Screen I/O Settings Screen
All documentation, software, program examples and resources are available
online at: http://www.imshome.com/mdrive34acplus_mdm.html
Specifications
Electrical Specifications
Input Voltage Range (120 VAC MDrive) 95 to 132 VAC @ 50/60 Hz
Input Current (120 VAC MDrive) 4.2 Amps
Input Voltage Range (240 VAC MDrive) 95 to 264 VAC @ 50/60 Hz
Input Current (240 VAC MDrive) 2.1 Amps
Environmental Specifications
Operating Temperature
(non-condensing)
Heat Sink -40°C to +75°C
Motor -40°C to +90°C
Sealing (-65 Only) IP-65 Compliant
Isolated Input Specifications
Step Clock, Direction and Enable
Voltage Range (Sinking or Sourcing) +5 to +24 VDC
Current (+5V Max) 8.7 mA
Current (+24V Max) 14.6 mA
Motion Specifications
Digital Filter Range 50 nS to 12.9 µS (10 MHz to 38.8 kHz)
Clock Types Step/Direction, Up/Down, Quadrature
Step Frequency (Max) 5 MHz
Step Frequency Minimum Pulse Width 100 nS
Number of Microstep Resolution Settings 20
Available Microsteps Per Revolution
200 400 800 1000 1600 2000 3200 5000 6400 10000
12800 20000 25000 25600 40000 50000 51200 36000
1
21600
2
25400
3
1=0.01 deg/µstep 2=1 arc minute/µstep 3=0.001 mm/µstep
Protection Specifications
Thermal
Internal Fuse (Line-Neutral Systems Only, Line-Line Systems Require External Fusing)
Temp. Warning Output Specifications
Type Open Drain
Drain-Source Voltage +5 to +24 VDC
Drain Current 50 mA
Setup Parameters
Setup Parameters
Name Function Range Units Default
MHC Motor Hold Current 0 to 100 Percent 5
MRC Motor Run Current 1 to 100 Percent 25
MSEL Microstep Resolution
See Motion
Specifications
µsteps/
Full Step
256
DIR
Motor Direction
Override
0/1 CW
HCDT
Hold Current Delay
Time
0 or 2 - 65535 mSec 500
CLK TYPE Clock Type
See Motion
Specifications
Step/
Direction
CLK IOF Clock Input Filter
50 nS to 12.9 µS
(10 MHz to 38.8
kHz)
nS (MHz)
200 nS
(2.5 MHz)
EN ACT
Enable Active High/
Low
High/Low High
USER ID User ID
3 Characters
Viewable ASCII
Viewable
ASCII
IMS
WARN TEMP Warning Temperature 0 to +125 °C 80
Dimensions in inches (mm)
Motor Length
LMAX1
(Single Shaft or
Internal Encoder)
LMAX2
(Control Knob)
Single 6.1 (155.0)
7.1 (180.4)
Double 6.9 (174.3)
7.9 (199.7)
Triple 8.4 (214.3)
9.4 (239.79)
L
MAX1
L
MAX2
1.46
(37.0)
0.87
(22.0)
Ø 0.55
(Ø 14.0)
0.40
(10.1)
0.08
(2.0)
2.70
(68.4)
3.38 SQ.
(85.8 SQ.)
5.76
(146.2)
6.47
(164.2)
2.74 SQ.
(69.58 SQ.)
Ø 2.87
(Ø 73.0)
3.46
(87.8)
0.63
(16.0)
Page view 0
1 2

Summary of Contents

Page 1 - Microstepping

Mechanical SpecificationsMDrive34AC Plus Microstepping Quick Reference R070208Quick ReferenceMDrive34AC PlusMicrosteppingNotes and WarningsInstallatio

Page 2 - AC Power

P1 Connector Style Function19-pin M23 circular..... I/O, Communications and Encoder3-pin Euro AC...... PowerMDrive34AC PlusMi

Comments to this Manuals

No comments